Rules of thumb (1 oz copper, outer layer, 10 °C rise)

1 A · 0.30 mm2 A · 0.78 mm3 A · 1.37 mm5 A · 2.77 mm

Width grows faster than current, inner layers need about 2.6× more, and on low-voltage rails the voltage drop usually forces you wider than heat does. The calculator below handles all three.

Every trace on a PCB is a resistor. Push current through it and it warms up and drops voltage, exactly as Ohm’s law predicts. Make it too thin and the copper overheats, delaminates or simply leaves your chip short of volts; make everything wide “to be safe” and the board won’t route. This guide shows how to size traces properly with the industry-standard IPC-2221 formula, a calculator you can use on real designs, and the practical rules we apply when laying out boards. If the Ohm’s law side is new to you, start with our Ohm’s law guide, which works through a trace’s resistance by hand.

Why trace width matters

A trace has two jobs that can both fail:

  • Carrying current without overheating. The power lost in a trace is P = I² × R. Double the current and the heat goes up four times. Too much heat discolours the board, lifts pads, weakens the fibreglass and, in the worst case, fuses the trace like a wire fuse.
  • Delivering the voltage intact. Even a cool trace drops V = I × R. On a 3.3 V rail, a 0.15 V drop is already 5%: enough to reset a microcontroller (see why an ESP32 keeps resetting).

Signal traces carry milliamps, so their width is set by impedance, routing density and what your fab can make. It’s power and ground traces (supply rails, motor and LED drivers, battery and charging paths) that need calculating.

Cross-section of a four-layer board: outer traces lose heat to air, inner traces are surrounded by fibreglass width W thickness t (1 oz ≈ 35 µm) Outer trace: heat escapes to air Inner trace: heat trapped in FR-4 FR-4 fibreglass
Current capacity depends on the copper’s cross-section (W × t) and how easily the trace sheds heat. That’s why inner layers need wider traces.

The IPC-2221 formula

IPC-2221, the general standard for PCB design, gives an empirical formula relating current, temperature rise and copper cross-section:

I=k×ΔT0.44×A0.725 I in amps · ΔT in °C · A in square mils
SymbolMeaningValue
kLayer constant0.048 for outer layers, 0.024 for inner layers
ΔTAllowed temperature rise above ambientCommonly 10 °C; 20–30 °C where heat is acceptable
ACopper cross-section, width × thicknessIn mil² (1 mil = 0.0254 mm)

To find the width, rearrange for the area and divide by the copper thickness:

A=(Ik×ΔT0.44)10.725cross-section needed
W=At×1.378width in mil, t in oz

The 1.378 converts copper weight to thickness: 1 oz of copper is 1.378 mil (35 µm) thick. The odd exponents come from curve-fitting test data, not physics, which is why the formula only claims to be valid up to about 35 A and 400 mil (10 mm) wide.

Trace width calculator

Minimum width0.30 mm11.8 mil
Resistance86.6 mΩat 35 °C
Voltage drop86.6 mVat 1 A
Power lost86.6 mWas heat in the trace
IPC-2221 with 25 °C ambient; resistance uses copper’s resistivity (1.72 × 10⁻⁸ Ω·m) corrected to the trace’s operating temperature. A conservative first estimate, not a substitute for IPC-2152 on demanding designs.

Quick reference table

Minimum widths from IPC-2221 for a 10 °C temperature rise:

Current1 oz, outer2 oz, outer1 oz, inner
0.5 A0.12 mm (4.5 mil)0.06 mm*0.30 mm (11.8 mil)
1 A0.30 mm (11.8 mil)0.15 mm (5.9 mil)0.78 mm (30.8 mil)
2 A0.78 mm (30.8 mil)0.39 mm (15.4 mil)2.03 mm (80 mil)
3 A1.37 mm (53.8 mil)0.68 mm (26.9 mil)3.56 mm (140 mil)
5 A2.77 mm (109 mil)1.38 mm (54.4 mil)7.19 mm (283 mil)
10 A7.19 mm (283 mil)3.60 mm (142 mil)Use a copper pour

* Below what most fabs can make. Use at least your fab’s minimum trace width, typically 0.1–0.15 mm (4–6 mil).

Copper weightThicknessSheet resistance (20 °C)Typical use
0.5 oz17.5 µm (0.69 mil)≈ 1.0 mΩ/□Inner layers, fine-pitch HDI
1 oz35 µm (1.38 mil)≈ 0.49 mΩ/□The default for most boards
2 oz70 µm (2.76 mil)≈ 0.25 mΩ/□Power boards, motor drivers, LED drivers
3 oz105 µm (4.13 mil)≈ 0.16 mΩ/□High-current power; limits fine pitch

Sheet resistance is the resistance of any square of copper, whatever its size: a trace’s resistance is its length divided by its width (the number of “squares”) times this figure. A 1 oz trace 100 mm long and 1 mm wide is 100 squares, so about 49 mΩ.

Worked examples

Example 1: an ESP32’s 3.3 V rail (voltage drop wins)

A 3.3 V regulator feeds an ESP32 module 80 mm away, with Wi-Fi peaks of 0.6 A, on 1 oz outer copper. By heat alone, IPC-2221 says 0.15 mm is enough. But check the drop:

0.15 mm × 80 mm at ~35 °C ≈ 0.28 Ω → 0.6 A × 0.28 Ω ≈ 0.17 V (5% of 3.3 V)

That’s too much on a rail with a 3.0 V minimum. Widening to 0.5 mm cuts it to about 0.083 Ω and 0.05 V (1.5%). Better still, place the regulator close to the module, or use a copper pour. On low-voltage rails, design for voltage drop first.

Example 2: a 5 A motor driver (heat wins)

A motor driver switches 5 A on 2 oz outer copper, and you accept a 20 °C rise near the driver.

IPC-2221: minimum width ≈ 0.91 mm

We’d draw it at 1.5–2 mm or as a pour for margin, and give the return path the same width: the ground side carries the same 5 A. Use several vias wherever the current changes layer.

Practical rules we use

  1. Calculate power traces; don’t guess. Signals can use your default width; supply, motor, LED and battery paths can’t.
  2. Check voltage drop as well as heat, especially on 3.3 V and lower rails, and on long runs.
  3. Size the return path too. Ground carries the same current. A solid ground plane is the best return of all.
  4. Use copper pours for high current. Above a few amps, a polygon is easier to route and cooler than a very wide trace.
  5. Watch the bottlenecks. A wide trace that necks down to a thin pad entry, a thermal-relief spoke or a single via is only as strong as its narrowest point.
  6. Use enough vias. A typical small via (0.3 mm drill) carries roughly 1 A comfortably; use several in parallel for power, placed where the current actually flows.
  7. Keep hot traces away from sensitive parts. A 20 °C rise next to a temperature sensor or crystal oscillator will show up in your readings.
  8. Leave margin. Ambient inside an enclosure is often 40–50 °C, not 25 °C. If the trace is near hot components, assume less headroom.

For professionals: IPC-2152 and real boards

IPC-2221’s formula comes from charts based on 1950s test data. In 2009 IPC-2152 replaced them with modern measurements, and showed that the picture is more nuanced:

  • Inner layers aren’t as bad as 2221 says. Its “inner = half the current” rule is very conservative for typical boards; in IPC-2152 testing, inner traces often ran cooler than outer ones, because the surrounding copper planes spread the heat.
  • Board thickness and copper planes matter. A trace above a solid plane runs much cooler; a lone trace on a thin board runs hotter. IPC-2152 provides correction factors for both.
  • Neighbours add up. Several current-carrying traces side by side heat each other; the standard’s single-trace numbers don’t account for that.

Use IPC-2221 for quick, conservative sizing and IPC-2152 (through its charts or tools such as the Saturn PCB Toolkit) when space is tight or currents are high. For the final word on a power board, a thermal camera on a prototype beats any formula. For high-frequency and fast-edge signals, width is set by impedance (for example 50 Ω single-ended or 90 Ω USB differential), which depends on the layer stack-up, not on current.

Common mistakes

  1. Using the outer-layer width on an inner layer. It needs to be about 2.6× wider for the same IPC-2221 rise.
  2. Sizing for average current. Size for the peak or the RMS current the trace actually sees, not the average.
  3. Forgetting the return path. A thin ground trace undoes a wide supply trace.
  4. Relying on solder to carry current. Opening the solder mask and tinning a trace helps a little but is hard to control in production. Use copper.
  5. Ignoring the fab’s 0.5 oz base copper. Some fabs start outer layers at 0.5 oz and plate up to about 1 oz; check what “1 oz” means on your order.

Practice problems

Use the formula or the calculator, then open the answer.

1What minimum width does a 2 A trace need on 1 oz outer copper with a 10 °C rise?

0.78 mm (30.8 mil).

2The same 2 A trace has to move to an inner layer. How wide now?

2.03 mm: about 2.6× wider, because IPC-2221 halves the current for inner layers.

3Your design uses 0.25 mm traces on 1 oz outer copper. How much current can they carry for a 10 °C rise?

About 0.88 A. Fine for signals and small loads, not for a motor or LED strip.

4If you switch the board from 1 oz to 2 oz copper, what happens to the width a given current needs?

It halves. The formula depends on cross-section, and doubling the thickness doubles the area for the same width. 2 A on 2 oz outer needs 0.39 mm.

5For professionals: a 10 A path on 2 oz outer copper, 30 mm long, with a 20 °C rise allowed. Find the minimum width, its resistance, voltage drop and power loss.

Width ≈ 2.36 mm. At about 45 °C, R ≈ 1.72 × 10⁻⁸ × 0.03 ÷ (2.36 mm × 70 µm) × 1.098 ≈ 3.4 mΩ, so about 34 mV dropped and 0.34 W of heat. In practice, use a pour with margin.

Summary

  • Size power and ground traces; signal traces are set by routing and impedance.
  • IPC-2221: I = k × ΔT0.44 × A0.725, with k = 0.048 outside and 0.024 inside.
  • Rules of thumb on 1 oz outer copper: about 0.3 mm per amp at low currents, growing faster above 2 A.
  • Always check voltage drop on low-voltage rails, size the return path, and use pours and multiple vias for high current.
  • Reach for IPC-2152 when the design is tight; it’s more accurate and usually less pessimistic.

Laying out a power board and want a second opinion on the copper? That’s part of every PCB design project we take on. Questions about your own traces are welcome in the comments.

Frequently asked questions

How wide should a PCB trace be for 1 amp?

About 0.3 mm (12 mil) on an outer layer of 1 oz copper for a 10 °C temperature rise, using IPC-2221. On an inner layer it needs about 0.78 mm. Use wider traces where voltage drop matters.

How much current can a 0.25 mm trace carry?

Roughly 0.9 A on an outer layer of 1 oz copper with a 10 °C rise. Inner layers carry less for the same width, because the heat has nowhere to go.

Why do inner layers need wider traces?

Outer traces lose heat to the air; inner traces are buried in fibreglass, which insulates them. IPC-2221 assumes inner traces carry half the current of outer ones for the same temperature rise, though the newer IPC-2152 shows this is often too pessimistic.

What is the difference between IPC-2221 and IPC-2152?

IPC-2221 is the older, simpler formula from 1950s test data. IPC-2152 (2009) is based on newer testing and accounts for board thickness, copper planes and material. IPC-2221 is usually conservative, which makes it a safe quick check.

What does 1 oz copper mean?

One ounce of copper spread over one square foot, which works out to about 35 µm (1.38 mil) thick. 2 oz is about 70 µm. It’s the standard way PCB fabs quote copper thickness.

Comments

No comments yet. Questions, corrections and your own tips are all welcome.

Leave a comment

Comments are reviewed before they appear. Your email is never shown.